What happens when the data changes?
A strong model on a familiar test set can fail when the operating regime or fault mode changes. We tested two independently trained FD001 models against four official NASA C-MAPSS cohorts without target-cohort retraining, then explored training on three development cohorts to test the fourth.
Original independent 48-wide compact temporal QA model, not OpenTime 5B.
Two fault modes and six operating conditions; severe false-alarm burden.
Separate classical regression model trained on FD001/2/3 development; FD004 held out.
Development-selected threshold; FD004 not used for training or selection. Classical CPU model, not the organizer 5B checkpoint.
Frozen FD001 models across four cohorts
The models and their decision thresholds were frozen before this cross-cohort evaluation. Bars are 30-cycle warning F1, not general aviation performance. Both independent models are different from the organizer's 5B checkpoint.
Read the failure modes, not just F1
The compact warning head can detect many at-risk engines after a shift but issues numerous false alarms. Remaining-useful-life error also increases. The total sample excludes engines whose observed history is shorter than the required 30-cycle window.
| Cohort | Evaluated / total | Classical F1 | Compact F1 | Classical MAE cycles | Compact MAE cycles | Compact false alarms | Compact misses |
|---|---|---|---|---|---|---|---|
| FD001Familiar conditions and one fault mode | 100 / 100 | 0.889 | 0.960 | 19.40 | 19.04 | 1 | 1 |
| FD002Six conditions, one fault mode | 253 / 259 | 0.000 | 0.624 | 33.85 | 37.32 | 69 | 2 |
| FD003One condition, two fault modes | 100 / 100 | 0.500 | 0.588 | 28.03 | 36.95 | 28 | 0 |
| FD004Six conditions, two fault modes | 237 / 248 | 0.000 | 0.479 | 39.53 | 52.42 | 112 | 1 |
Official simulation test engines: FD001 100/100, FD002 253/259, FD003 100/100, FD004 237/248. No engine is represented twice in a cohort's endpoint evaluation.
What we changed after observing transfer failure
Binary 30-cycle warning F1. It missed every at-risk test engine at the fixed threshold.
MAE 30.41 cycles; TP 27, FP 4, FN 26, TN 180, over 237 eligible held-out engines.
Precision 88.9% · Recall 75.5% · Correct warnings 40 · False alarms 5 · Misses 13 · Correct non-warnings 179.
Trained on the same FD001/FD002/FD003 development cohorts, using a separate classical gradient-boosted classifier. Its probability threshold (0.40) was selected on those cohorts' engine-disjoint development validation set only. The full FD004 official test set remained held out. Inspect original verified classifier job.
These are post-hoc, exploratory adaptations following observed failure of the FD001-only models, not preregistered comparisons. Training used separate engine-disjoint development splits within FD001, FD002 and FD003. No FD004 data were used to train, validate or select either multi-domain model. The direct-warning classifier still missed 13 at-risk simulated engines.
What this means for a real product
Projects tested on real-world turbine data address different assets and tasks. These NASA simulations cover a related engine family and do not establish cross-manufacturer generalization. Our results are not a direct leaderboard comparison.
Reproduce and challenge the evidence
- Original frozen classical model, all four official NASA test subsets
- Original verified compact model checkpoint, evaluated with no retraining
- Exploratory FD001/FD002/FD003 to held-out FD004 multi-domain regression
- Exploratory direct-warning classifier: validation-selected threshold, held-out FD004
- NASA source archive, checksum-verified by each experiment
- Separate upstream TimeNet dataset connector PR #836
- Evidence-based 90-second judges' walkthrough
All figures come from public GitHub Actions logs and their machine-readable artifacts. Aggregates only: no NASA source tables, per-engine labels or trained model weights are redistributed. Dataset source usage rights remain subject to review.